Commercial

Shops, offices, clinics and kitchens

Commercial ventilation carries an obligation residential work does not, and unlike most obligations this one can actually be measured. That is where we start.

The survey

Every unit found, and the outdoor air actually reaching the floor

First the plant: every unit located and identified by model and serial number, matched to the area it actually serves, its measured condition recorded, and dead or abandoned equipment marked as dead. On a building that has changed tenants twice, some of it will not be connected to anything.

Then the part most surveys skip. Outdoor air dampers get checked for whether they still move, economisers for whether they still modulate, and the actual outdoor air reaching the space gets measured rather than assumed from a drawing that may be thirty years old. In a tenanted building, a damper wired shut years ago to save energy is a completely ordinary finding.

The survey is written so a manager who has never been on the roof can use it, and so a landlord and a tenant can tell who is responsible for what.

Packaged units and extract terminals on the flat roof of a single-storey commercial parade, with ducts, disconnects and a parapet edge.
By premises

Four kinds of building, four different problems

Shops and shopfronts

A door standing open all day is a trading decision and not ours to argue with, but it does mean the plant is conditioning the sidewalk. The honest options are an air curtain, a schedule change, or a figure on the bill, and we will put numbers against all three. Where a shop is genuinely sealed, the outdoor air rate becomes the question instead, and that is measurable.

Offices

Usually a zoning problem wearing a capacity problem’s clothes: one thermostat governing a floor with glass at one end and an interior corridor at the other. We measure the zones separately at the hour the complaints happen, which is nearly always mid-afternoon. Then we check whether the outdoor air damper has moved this decade.

Medical and dental suites

Stable temperature, documented filter changes, and ventilation that can be shown to be doing what the room requires. We keep the records in a form an inspector will accept. Where a space needs formal certification to a clinical standard, that is a specialist engagement and we will say so rather than take it on.

Restaurants and kitchens

Make-up air balanced against hood exhaust, measured rather than assumed. A kitchen out of balance pulls conditioned air from the dining room and the street and makes the front of house impossible to control. We work on the air. We do not clean hoods and we do not certify fire suppression.

Commercial services

What we do in premises

  • Written plant survey

    Every unit found, identified, measured and mapped to what it serves, with abandoned plant marked as dead.

  • Outdoor air measurement

    Dampers and economisers checked for whether they still move, and the air actually reaching the space measured, dated and written down with the method.

  • Planned maintenance

    Scheduled visits, the same readings each time, written specifically enough that a lease obligation can be shown to have been met.

  • Repair and replacement

    Repair diagnosed and costed first. Replacement sized from the load the building carries now.

  • Make-up air and exhaust balance

    Kitchen and workshop extraction measured against supply, with the figures written down.

  • Zoning and controls

    Sensors where the complaints are, schedules set to the hours the building is used.

Not us

Work we turn down

We declineWho it belongs to
Certifying ventilation complianceWe measure and document outdoor air rates with the method and the date. Whether the result satisfies an obligation is for a code official or an engineer to say, and we will not say it for them.
Mould testing and remediationWe find the moisture source, which is mechanical. Testing, identification and removal belong to an industrial hygienist and a remediation contractor.
Central chiller plant and cooling towersA different discipline with different tickets, and we are not going to learn it on your building.
Proprietary building management systemsWe will work with the controls in front of us and tell you what a schedule is doing. Programming a manufacturer-locked system belongs to whoever holds the licence.
Commercial refrigerationWalk-ins, display cases and ice machines are adjacent and are not the same trade.
Hood cleaning and fire suppressionSeparate licensed jobs. We do the air balance around the hood.
Clinical certificationWhere a space must be certified to a clinical standard we hand it to a specialist rather than sign something we are not qualified to sign.
Ask for a survey

Tell us the building

What it is used for, roughly how many units are on the roof, and whether the complaints are about temperature or about the air. 3213 W Imperial Hwy, Inglewood. Monday to Friday, 8am to 5pm.